Electrical lockout procedures must be followed and safe isolation from supply voltage must be verified before work can commence on electrical equipment or installations. By locking-out, testing for voltage, earthing and barricading, electrical equipment and installations can be made safe to work on.

ELECTRICAL SAFETY EQUIPMENT INFORMATION
- Discharge Rods to discharge static charges from cables and capacitors,
- Rescue Rods to remove personnel from the live working zone in the event of an electrical accident,
- Fuse Tongs for the removal of high voltage fuses,
- Earthing Rods for the installation of portable earthing equipment on busbars and overhead lines,
- Switching Rods to perform switching operations on electrical equipment and to switch links and drop-out fuses on overhead lines.
The cleaning equipment is designed for the cleaning of electrical installation under live conditions, and for voltages up to 36kV/15Hz to 60Hz. Dry cleaning work is performed by suction cleaning with operating heads or brushing soiled parts of the installation while simultaneously sucking the dirt away. Loose layers of dust and pollutants are easily removed with little effort. Damp cleaning eliminates oily and tough contaminants with the help of sponges soaked with special insulating cleaning liquids.
- For indoor and outdoor installations
- Combined dry and damp cleaning kit for cleaning under live conditions
- Transparent intake tubes ensure enhanced safety
- Universal gear coupling for replacing and adjusting the angle of operating heads
- Rigid and flexible plug-in operating heads allow fast and easy replacement of the sponges



ELECTRICAL SAFETY EQUIPMENT DATA SHEETS
- Voltage Detector Series PHE III & PHE III ZK - 3kV to 33kV 50Hz
- Voltage Detector Series PHE III Kits - 20kV to 110kV 50Hz
- Voltage Detector Series PHE4 - 1kV to 36kV 50Hz
- Voltage Detector Series PHE4 - 3,3kV to 33kV 50Hz
- Voltage Detector Series PHE4 - 30kV to 420kV Hz
- Test Prods for Voltage Detector PHE III
- Voltage Detector Series PHE III, PHE III ZK and PHE4 - Contact Electrodes and Test Probes
- Storage Bags and Transport Cases
- Earth Connecting Clamps for Railway Applications
- Earth Connecting Clamps for Switchgear Installations and Overhead Lines
- Earth Connecting Plates
- Earthing and Short-Circuiting Cables, without clamps
- Earthing and Short-Circuiting Device for Street Lighting Systems
- Earthing and Short-Circuiting Devices (fully insulated) for Low-Voltage Cable Distribution Cabinets
- Earthing and Short-Circuiting Devices (partly insulated) for Low-Voltage Cable Distribution Cabinets
- Earthing and Short-Circuiting Devices for Crane Conductor Bars
- Earthing and Short-Circuiting Devices for Railway Applications
- Earthing Handle for Low-Voltage Installations
- Fixed Ball Points
- Fixed Earth Points
- Kits for Railway Applications
- Phase Connecting Clamps for Overhead Lines
- Phase Connecting Clamps for Railway Applications
- Phase Connecting Clamps for Switchgear Installations
- Short-Circuiting Bars
- Arc Fault Protection Gloves
- Arc Fault Protection Face Shields
- Arc Fault Protection Face Shield - with active protection (785821)
- Arc Fault Protection Face Shield - with active protection (785822)
- Arc Fault Protection Face Shield - with active protection (785823)
- Arc Fault Protection Face Shield - with active protection (785824)
- Arc Fault Protection Face Shield - with active protection (785825)
- Arc Fault Protection Face Shield - with active protection (785826)
- Safety Helmet for Electricians